Sophos-branded physical appliance LCD panel
The LCD panel is the two-line display and four-button keypad on the front of Sophos-branded physical appliances. You can use it to view appliance information and troubleshoot the appliance when network access isn't available.
This page explains how to use the panel, navigate its menus, and understand the activation screens.
When to use the panel
Use the LCD panel when you can't access the appliance remotely.
If the appliance is available on the network, you can use the web console to see more detailed information. You can also use the serial console to view the LCD panel information as text. See Sophos-branded physical appliance web console and Sophos-branded physical appliance serial console.
The LCD panel shows different screens before and after appliance activation. Before activation, it shows the activation process. After activation and setup, it shows the appliance menus.
Panel buttons
To navigate the menus, use these buttons.
| Button | What it does |
|---|---|
| Enter | Opens a menu, selects an item, or refreshes the result on the screen |
| Esc | Goes back one level |
| Up | Scrolls up in a menu, or raises the brightness on the home screen |
| Down | Scrolls down in a menu, or lowers the brightness on the home screen |
When you're looking at the result of an action, such as "Show Date", "Show CPU", or "Ping Gateway", Enter runs the action again and refreshes the information. Esc takes you back to the menu. The Up arrow and Down arrow don't do anything on a result screen.
Reading the panel
The home screen
After the appliance is activated and set up, the panel shows the firmware version on the first line and the serial number on the second.
Example
NDR v9.3.2.2
SN: ABC123
The firmware version identifies the appliance firmware. NDR software updates don't change it, so it might not match the NDR version shown in Sophos Fusion. The NDR version changes when the NDR software is updated.
The serial number identifies the appliance in Sophos Fusion and can also be useful when you contact Sophos Support.
Press Enter to open the main menu. If you don't press a button for an hour while a menu is open, the panel returns to the home screen.
A blank panel
If the panel is blank, the backlight might be turned off. The Up arrow and Down arrow adjust the backlight brightness on the home screen from 1 to 8. Pressing Down arrow when the brightness is at level 1 turns off the backlight.
When the backlight is off, press any button to turn it on at brightness level 1. This first button press only turns on the display and doesn't perform the button's usual action.
Press Up arrow several times before assuming that the display or appliance has a problem. The appliance saves the brightness setting and restores it after a restart.
Getting information from the panel
If you can't reach the web console or appliance CLI, use the LCD panel to find this information.
| Information | Location |
|---|---|
| Serial number and firmware version | Home screen or Firmware Menu > Show NDR Firmware |
| Dragonfly AI firmware version | Firmware Menu > Show AI Firmware |
| Date and time (UTC) | System Menu > Show Date |
| Uptime | System Menu > Show Uptime |
| CPU | System Menu > Show CPU |
| Memory | System Menu > Show Memory |
| Load | System Menu > Show LoadAvg |
| Disk | System Menu > Show Disk |
| EXTP address and link status | Network Menu > Show Port [EXTP] |
| Gateway | Network Menu > Show Gateway |
| DHCP status | Network Menu > Show DHCP |
| Gateway connectivity | Network Menu > Ping Gateway |
| Appliance mode | NDR Menu > Show Mode |
| Traffic rates, latency, and capture port link status | NDR Menu > Bridge or Port entries |
The Show Port [EXTP] screen shows the physical link status and IP address as follows:
- "UP" or "DOWN" indicates whether the port has a physical network connection. The link status doesn't indicate whether an IP address is assigned.
- If the EXTP interface doesn't have an IP address, the second line shows "IP NOT ASSIGN".
Example
Port [EXTP] UP
192.168.1.10/24
"Ping Gateway" sends a single ping and shows "Reachable", "Unreachable", or "No Gateway" if a gateway isn't configured. Press Enter to run the ping again.
A "Reachable" result only confirms connectivity to the gateway. It doesn't confirm that the appliance can reach the internet or Sophos services.
On the Sophos NDR 5500, EXTP refers to the port labeled EXTP on the front of the appliance.
Note
Don't use Show Port [MGMT] to check the management connection. Use Show Port [EXTP] or check the management network information in the web console.
Reading the NDR menu
The LCD shows one of the following traffic modes:
- "Inline Blocking" for active IPS modes.
- "Inline Passive" for passive IPS modes.
- "Sniffer" for NDR, NDR+IDS, and IDS modes.
The NDR menu changes based on how the appliance is processing network traffic.
- For inline traffic, the menu shows one entry for each bridge, which is a pair of capture ports. Each entry shows throughput, packets per second, latency, and the link status of both ports. For example, "A1:DOWN<->A2:UP" means that A1 is down and A2 is up. A bridge shows "[UP]" only when both ports are up.
- For sniffer traffic, the menu shows one entry for each capture port. Each entry shows throughput, packets per second, and link status.
- "Show Mode" shows the traffic mode as "Inline Blocking", "Inline Passive", or "Sniffer".
If traffic is passing at a very low rate, the panel shows "0.01 Mbps" instead of "0 Mbps".
The NDR menu isn't shown if the appliance can't determine its traffic mode.
Troubleshooting activation
Before activation is complete, the panel shows "[NDR Activation]" and displays the progress of the activation process. Most steps continue automatically. Follow the instructions on the panel if it asks you to take an action.
| What you see | What it means | What to do |
|---|---|---|
| "EXTP Port: NO LINK" | The EXTP port doesn't have a network link. | Check that the network cable is connected and the switch port has a link. The appliance continues automatically when the link becomes available. |
| "EXTP Port: DHCP" | The appliance is waiting for an IP address and gateway from DHCP. | Wait for the appliance to obtain its network settings. |
| "DHCP: FAILED" followed by "Config Static IP?" | The appliance didn't receive network settings from DHCP. | Check the network cable, switch port, and DHCP server. Follow the instructions on the panel if you want to configure a static IP address. |
| "Testing Network..." | The appliance is checking its network connection to Sophos services. | Wait for the test to finish. |
| "DHCP: FAILED" with "No Network Access", or "Static IP: FAILED" | The appliance has network settings but can't reach Sophos services. | Check the management network connection and the required outbound connectivity. |
| "Activating Device" | The appliance serial number is being activated with Sophos. | Wait for activation to finish. |
| "Activation: FAILED" followed by "Restarting..." | Activation wasn't successful. | Wait while the appliance restarts the activation process. |
| "Registering" | The appliance is registering with Sophos. | Wait for registration to finish. |
| "Registration: FAILED" with "Serial Number Unknown" | Sophos doesn't recognize the serial number during registration. | Check that the appliance serial number is correct and that you've claimed the appliance in Sophos Fusion. If registration continues to fail, contact Sophos Support. |
| "Updating Installer" | The installer is updating. | Wait for the update to finish. The appliance restarts automatically. |
| "Downloading" | The appliance is downloading the system image. | Wait for the download to finish. |
| "Installing NDR" | The appliance is installing the NDR image. | Wait for installation to finish. |
| "Install: Successful" followed by "Rebooting..." | Installation is complete. | Wait for the appliance to restart. |
For management network requirements, see Connectivity requirements.
For instructions on claiming an appliance, see Claim appliance.
If an activation, registration, download, or installation error appears, record the complete error message before you press a button. The appliance automatically retries failed operations. If the error continues, contact Sophos Support.
Contact Sophos Support
If you contact Sophos Support about an LCD panel or activation issue, have the following information available:
- Appliance serial number
- Firmware version shown on the LCD panel
- NDR version shown in Sophos Fusion
- Exact error message shown on the LCD panel